The Steel Scanner

JZT702

Watch

The spacing error of steel bars is plus or minus 2 mm, and the distribution map of bars can be shown (surface and profile).

Protection layer thickness measurement (nominal) range: first range (nominal) range: 6mm ~ 90mm second range (nominal) range: 7mm ~ 200mm;

Scope of steel bar diameter measurement (nominal) : 6 ~ Ф Ф 50 mm

The maximum allowable error range of the steel bar diameter measurement is: -1 gear

Host volume: 220 * 162 * 91mm

Power supply: charge battery, power supply time can reach 50 hours

Working environment: working temperature: - 10 ℃ ~ + 40 ℃, relative humidity (90% RH

The Steel Scanner

China The Steel Scanner Pictures&Photos



Working environment: 


working temperature: - 10 ℃ ~ + 40 ℃, relative humidity (90% RH


Technical features:


One-piece probe, easy to operate
Backlight design can be clearly displayed in a darker environment
It can be used in WinXP, Win7, Win8 and other environments


Main technical indicators:


The analysis software of the bar scanner of the China extension co
1. The spacing error of the steel bar is plus or minus 2 mm, and the distribution map of the steel bars can be displayed (plan and profile).
2. Extent of protective layer thickness measurement (nominal) range: first range (nominal) range: 6mm ~ 90mm; Range of second range (nominal) range: 7mm ~ 200mm;
3. The scope of steel bar diameter measurement (nominal) : 6 ~ Ф Ф 50 mm;
4. Maximum allowable error of reinforcement protection layer thickness measurement:

5.The maximum allowable error range of the diameter of steel bar is:
6. Working environment:
Working temperature: - 10 ℃ ~ + 40 ℃
Relative humidity: < 90% RH
7. Other requirements:
There is no corrosive gas in the air;
No strong electromagnetic interference;
There should be no greater vibration or shock;
The LCD screen avoids direct sunlight
8. Power supply: charge battery, power supply time can reach 50 hours
9. Host volume: 220 * 162 * 91mm
Instrument composition:
Includes: host, probe, cable, scanning car, software disc, etc.